Digital Pathology Second Opinion: How Remote Case Consultation Actually Works
A second opinion in pathology used to mean packing glass slides, booking a courier, and waiting days for a colleague to look at them. Digital pathology removes the courier. It does not remove the workflow problems that make consultations slow.
This article describes what a digital second opinion involves and where it tends to break down. It is written for pathology directors and the lab managers who run these workflows day to day.
What is a digital pathology second opinion?
A digital pathology second opinion is a consultation in which a pathologist reviews a case from a whole slide image (WSI) rather than from physical glass slides. The consulting pathologist can be in another department, another site, or another country. Slides are scanned once and then shared. Nothing needs to be shipped.
Why second opinions slow down
The scanner is rarely the delay. In practice, the time goes to four things:
Finding the right case. Slides sit in the scanner software while the clinical data sits in the LIMS, so someone has to match them by hand.
Sharing safely. Patient data must be removed or controlled before a case leaves the lab, and doing that by hand takes time and invites mistakes.
Communicating findings. Annotations, measurements, and questions often travel by email or screenshot, away from the case record.
Closing the loop. The consultant's opinion has to return to the original case report, or it is effectively lost.
Reported turnaround gains depend heavily on the setting. In one reference-laboratory consult program linking Labcorp Dianon and Mount Sinai, average turnaround fell from 86 hours with glass slides to 35 minutes with digital review, and most of the saving came from removing mail transit [1]. A California telepathology network took a more cautious view: its authors noted that domestic mail already leaves only about 24 hours or less to gain, although services that need same-day answers, such as transplant nephrology, benefit more [2].
What a working digital consultation workflow needs
Slides linked to the case record. The image opens from the case, not from a separate folder.
Controlled sharing. The referring pathologist chooses what the consultant sees, and identifying data is handled before sharing. Confirm exactly how your system does this.
Annotations that stay with the case. Measurements, regions of interest, and notes belong to the case, not to an email thread.
Standards-based integration. Connecting to the LIMS and EHR through HL7 and FHIR, and handling images in DICOM where scanners support it, avoids retyping data.
A clear audit trail. Who viewed what, and who gave which opinion, should be on record for accreditation.
Consultation also matters for diagnostic consistency. Different pathologists can read the same case differently, which is known as interobserver variability. In a retrospective series of 319 gynecologic second-opinion cases at one Italian referral centre, 53.0% showed some discrepancy with the referring diagnosis and 34.5% a major one. The authors caution that referred cases tend to be the difficult ones, which may inflate these rates [3]. A fast, low-friction second opinion is one practical way to manage this variability.
How SlidePath approaches this
SlidePath is a cloud-based whole slide image viewer and LIMS, built around the workflow at CSD LAB, a large private pathology laboratory in Ukraine. For consultations, it lets a pathologist open a case's slides in the browser, annotate them, and share the case with another pathologist without exporting files. It integrates with common LIMS and EHR systems and with scanners from major vendors.
SlidePath supports the pathologist's review. It does not make diagnoses, and the signing pathologist remains responsible for the final report.
What to check before choosing a platform
Does the consultant need a separate viewer licence?
How is patient data handled before a case is shared?
Do annotations and the consultant's opinion return to the original case record?
Which regulatory status applies in your country, and is each feature cleared for clinical use or still investigational?
What does the lab need to change on day one, and who trains the staff?
FAQ
Is a digital second opinion as reliable as one on glass slides?
It depends on validation. The College of American Pathologists guideline for validating whole slide imaging systems recommends a validation set of at least 60 cases, a comparison of each pathologist's digital and glass-slide diagnoses with a two-week washout period between them, and a closer look if overall concordance falls below 95% [4]. That guideline covers validating a system for diagnostic use and excludes cytology, so check what your accreditor and regulator require for consultation work. The authors of the Labcorp and Mount Sinai consult study also note that digital consultation has yet to be fully validated [1].
Do we need a new scanner?
Not necessarily. It depends on whether your current scanner's output formats are supported.
Can this work across countries?
Yes in principle, but data protection law (for example GDPR in the EU) and local regulation determine what is permitted.
Sources
[1] Haghighi M, et al. Whole Slide Imaging for Teleconsultation: The Mount Sinai Hospital, Labcorp Dianon, and Philips Collaborative Experience. J Pathol Inform. 2021;12:53. doi:10.4103/jpi.jpi_74_21
[2] Chong T, et al. The California Telepathology Service: UCLA's Experience in Deploying a Regional Digital Pathology Subspecialty Consultation Network. J Pathol Inform. 2019;10:31.
[3] Cianfrini F, et al. Rethinking certainty: a retrospective study on diagnostic revisions in gynecologic pathology. Int J Gynecol Cancer. 2026;36(2). doi:10.1016/j.ijgc.2025.102826
[4] Evans AJ, et al. Validating Whole Slide Imaging Systems for Diagnostic Purposes in Pathology: Guideline Update from the College of American Pathologists in Collaboration with the American Society for Clinical Pathology and the Association for Pathology Informatics. Arch Pathol Lab Med. 2022;146(4):440-450. doi:10.5858/arpa.2020-0723-CP